Especially in modern fermentation systems used for bread, pastries, and confectionery production, cooling fans are no longer simply auxiliary ventilation components. They are now essential parts of temperature and humidity control systems.
Under this trend, more manufacturers of Bakery and Confectionery Equipment are beginning to adopt PWM-controlled IP68 Splash Proof Fans instead of traditional voltage-controlled fans.
So why is this transition accelerating across the baking equipment industry?
This article analyzes the engineering reasons behind this trend from the perspectives of airflow management, environmental resistance, energy efficiency, and equipment reliability.
Modern bakery production involves a wide variety of products:
Sweet bread
Toast bread
Croissants
Frozen dough
Cakes and pastries
Fermented confectionery products
Different products require different fermentation conditions.
As a result, manufacturers are demanding more precise environmental control inside fermentation and proofing systems.
Key requirements now include:
Stable temperature
Uniform humidity
Controlled airflow
Reduced dough drying
Consistent fermentation quality
In many systems, airflow management directly affects final product quality.
Earlier bakery and confectionery equipment often controlled fan speed by adjusting input voltage.
However, this approach is becoming increasingly inadequate for modern precision fermentation systems.
When fan speed is adjusted through voltage reduction:
RPM control becomes unstable
Startup reliability decreases
Fine airflow adjustment becomes difficult
This makes precise fermentation control harder to achieve.
Modern proofing systems often require gentle low-speed airflow circulation.
However, traditional voltage-controlled fans may experience:
Rotation instability
Fan stalling
Inconsistent airflow
This can create uneven temperature and humidity distribution inside the chamber.
Modern Bakery and Confectionery Equipment often includes:
Fermentation mode
Moisture retention mode
Rapid recovery mode
Circulation mode
Each mode requires different airflow characteristics.
Traditional voltage regulation cannot easily achieve this level of airflow precision.

PWM (Pulse Width Modulation) control enables digital fan speed management through pulse signals instead of voltage reduction.
This provides several major advantages for bakery equipment manufacturers.
PWM control allows:
Stable low-speed operation
Wide RPM adjustment range
Accurate airflow management
For fermentation systems, this means:
✔ More consistent chamber temperature
✔ Better humidity uniformity
✔ Reduced uneven fermentation
This is especially important in commercial baking systems with large-capacity fermentation chambers.
Excessive airflow can dry the dough surface.
Insufficient airflow can lead to temperature stratification.
PWM-controlled fans allow manufacturers to dynamically optimize airflow according to operating conditions.
Benefits include:
Gentler air circulation
Better moisture preservation
Improved fermentation consistency
These factors directly influence final baking quality.
Modern bakery environments increasingly prioritize:
Lower operating noise
Reduced energy consumption
Improved workplace comfort
PWM-controlled fans only operate at the required speed.
This helps achieve:
| Benefit | Result |
|---|---|
| Lower RPM operation | Reduced noise |
| Dynamic speed control | Lower power consumption |
| Reduced motor stress | Longer service life |
| Optimized airflow | Improved system efficiency |
For equipment operating continuously for long production cycles, these advantages are highly valuable.
Inside bakery fermentation systems, the operating environment is often more severe than many engineers initially expect.
Typical conditions include:
High humidity
Water vapor
Flour dust
Condensation
Frequent cleaning
These environments can significantly shorten the lifespan of conventional cooling fans.
Fine flour particles can easily enter:
Motor coils
Bearings
Driver circuits
At the same time, high humidity and condensation can accelerate corrosion and electrical failures.
This is why IP68-rated Splash Proof Fans are increasingly preferred in Bakery and Confectionery Equipment.
A Splash Proof Fan is designed for environments exposed to water, dust, and moisture.
The motor coils and electronic components are protected using resin coating technology that helps prevent dust and water intrusion into live electrical components.
According to IEC 60529:
| Protection Rating | Description |
|---|---|
| IP54 | Splash-resistant |
| IP55 | Resistant to low-pressure water jets |
| IP68 | Complete dust protection and resistance to water immersion |
In high-humidity bakery environments, IP68 protection provides significantly better operational reliability.

Many bakery equipment manufacturers are increasingly evaluating San Ace Splash Proof Fans because they combine:
IP68 protection
PWM speed control
Long operating life
Stable low-speed operation
High environmental resistance
For modern Bakery and Confectionery Equipment, stable airflow control is often more important than simply maximizing airflow volume.
A bakery equipment manufacturer developing a new fermentation management system faced several technical challenges:
Voltage-based airflow adjustment range was limited
Fan operation became unstable at low speed
High humidity threatened fan reliability
Flour dust created contamination risks
The manufacturer eventually evaluated an IP68 PWM-controlled Splash Proof Fan solution.
After implementation, the engineering team achieved:
✔ More precise airflow management
✔ Stable low-speed operation
✔ Improved fermentation consistency
✔ Better dust and moisture resistance
✔ Easier control integration
Additionally, customized lead wire extensions helped eliminate unnecessary connector joints, improving hygiene and environmental resistance.
This became an important advantage for food-grade equipment design.
Modern Bakery and Confectionery Equipment often requires customized cooling fan configurations, including:
Extended lead wires
Waterproof connectors
PWM control
FG speed signal
RD alarm signal
Customized mounting structures
As equipment designs become thinner and more compact, standard fan configurations are often insufficient.
This increases the importance of engineering-oriented cooling fan suppliers.
The bakery equipment industry is gradually moving toward:
Smart fermentation control
Intelligent airflow management
Energy-saving operation
IoT monitoring
Predictive maintenance
Under these trends, PWM-controlled IP68 Splash Proof Fans are becoming key airflow control components rather than simple cooling accessories.
The increasing adoption of PWM-controlled IP68 Splash Proof Fans in Bakery and Confectionery Equipment reflects broader industry trends toward:
More precise fermentation management
Higher hygiene standards
Greater reliability
Lower energy consumption
Intelligent airflow control
Compared with traditional voltage-controlled fans, PWM-controlled Splash Proof Fans provide:
More stable airflow
Better low-speed control
Improved humidity management
Lower noise
Enhanced dust and water resistance
As modern bakery equipment continues evolving toward higher precision and smarter system control, PWM-controlled IP68 Splash Proof Fans are expected to become a mainstream solution in next-generation Bakery and Confectionery Equipment.
jamicon cooling fan,AVC cooling fan,jentech cooling fan,AVC fan
| 型号 |
产品 名称 |
额定 电压 (V) |
额定 电流 (A) |
额定 功率 (W) |
额定 转速 (min-1) |
最大 气流 (CFM) |
最大 静压 (Pa) |
噪音 (dBA) |
预期 寿命 (h) |
IP防护 等级 |
PWM控制功能 |
| 9WPA1212G4001 | Splash Proof Fan | 12 | 0.5 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212G40011 | Splash Proof Fan | 12 | 0.5 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212H4001 | Splash Proof Fan | 12 | 0.12 | 1.44 | 2400 | 65 | 47 | 30 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212H40011 | Splash Proof Fan | 12 | 0.12 | 1.44 | 2400 | 65 | 47 | 30 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212J4001 | Splash Proof Fan | 12 | 1 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212J40011 | Splash Proof Fan | 12 | 1 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1212P4G001 | Splash Proof Fan | 12 | 0.5 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1212P4G0011 | Splash Proof Fan | 12 | 0.5 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1212P4J001 | Splash Proof Fan | 12 | 1 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1212P4J0011 | Splash Proof Fan | 12 | 1 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1224G4001 | Splash Proof Fan | 24 | 0.25 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224G40011 | Splash Proof Fan | 24 | 0.25 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224H4001 | Splash Proof Fan | 24 | 0.06 | 1.44 | 2400 | 65 | 47 | 30 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224H40011 | Splash Proof Fan | 24 | 0.06 | 1.44 | 2400 | 65 | 47 | 30 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224J4001 | Splash Proof Fan | 24 | 0.5 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224J40011 | Splash Proof Fan | 24 | 0.5 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | No |
| 9WPA1224P4G001 | Splash Proof Fan | 24 | 0.25 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1224P4G0011 | Splash Proof Fan | 24 | 0.25 | 6 | 4250 | 117 | 135 | 46 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1224P4J001 | Splash Proof Fan | 24 | 0.5 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | Yes |
| 9WPA1224P4J0011 | Splash Proof Fan | 24 | 0.5 | 12 | 5400 | 148 | 210 | 53 | 40000/60℃ (70000/40℃) | IP68 | Yes |
Contact: Mr. Wang
Phone: 18038149909
Tel: 0755-23706799
Email: whd@jentech.cn
Add: No. 28, Tongyuwu Industrial Zone, Kuikeng Community, Guanlan Street, Longhua District, Shenzhen City. 6th floor, Building 1, Hualangjia Industrial Park